← Drop-Test Database

Schmidt & Bender Klassik 8x56 (fixed)

Data Provenance

Who tested: Rokslide field eval (2022-01) — read the original write-up, which is the source of record. Who structured it: Optics Intel. We extract outcomes and cite; the testing labor is theirs.

Sample size: 1 (single unit) — evidence about this unit, not a verdict on every unit shipped.

Stage-by-stage record

Tracking / RTZNot testedexplicitly not conducted beyond zeroing
18″ dropsPassfull repeat eval clean after remount; first attempt slipped in the rings at 18 in-lb
36″ (single)Pass
3×36″Passall rounds at baseline group size through the repeated eval
Long-termNot tested

Mount setup

Rings/mount: caps 18→20 in-lb after ring slip on the first attempt. Ring torque: 20 in-lb. No torque caveat flagged in the source.

Notes

First-attempt zero loss traced to visible ring slip at 18 in-lb; the remounted eval passed everything run.

What this eval didn't test

Tracking / RTZ, Long-term — these stages are shown as not tested, never assumed. If a later source covers them, this row is updated and the change is logged.

Spot an error — or is this your eval and you want to annotate or dispute the row? Contact us. Corrections are logged publicly on the provenance page.