Maven RS.6 1-10x28

Data Provenance

Who tested: Rokslide field eval (2024-12) — read the original write-up, which is the source of record. Who structured it: Optics Intel. We extract outcomes and cite; the testing labor is theirs.

Sample size: 1 (single serial number) — evidence about this unit, not a verdict on every unit shipped.

Stage-by-stage record

Tracking / RTZFailturret rev-indicator skipped and locked twice during RTZ; adjustment value off 7% at 7.2 mils
18″ dropsShift0.1 mil up / 0.1 mil right on the first 18″ right drop; did not move again
36″ (single)Pass
3×36″Pass
Long-termNot tested

Mount setup

Rings/mount: degreased. Ring torque: 20 in-lb. Torque caveat: the source flags mount-torque questions for this eval — weigh the results accordingly.

Notes

Drop shift minor and possibly ring-cap-torque related per source (drop eval may be redone); a bent internal zero-stop ring was photographed as the likely cause of the turret lockups.

What this eval didn't test

Long-term — this stage is shown as not tested, never assumed. If a later source covers it, this row is updated and the change is logged.