← Drop-Test Database

Maven CRS.3 4-20x50

Data Provenance

Who tested: Rokslide field eval (2025-08) — read the original write-up, which is the source of record. Who structured it: Optics Intel. We extract outcomes and cite; the testing labor is theirs.

Sample size: 1 (single serial number) — evidence about this unit, not a verdict on every unit shipped.

Stage-by-stage record

Tracking / RTZPassRTZ clean — returned to zero perfectly after the drops
18″ dropsFailshifted in the expected direction with every drop
36″ (single)Fail36″ drops shifted farther than 18″ drops
3×36″Failfailed across the board, but returned to zero once the drops stopped
Long-termNot tested

Mount setup

Rings/mount: degreased. Ring torque: 20 in-lb. No torque caveat flagged in the source.

Notes

Distinct failure mode: shifts under drops, then snaps back to zero at rest. Source also flags murky glass above 16x.

What this eval didn't test

Long-term — this stage is shown as not tested, never assumed. If a later source covers it, this row is updated and the change is logged.

Spot an error — or is this your eval and you want to annotate or dispute the row? Contact us. Corrections are logged publicly on the provenance page.