March FX 4.5-28x52

Data Provenance

Who tested: Rokslide field eval (2023-11) — read the original write-up, which is the source of record. Who structured it: Optics Intel. We extract outcomes and cite; the testing labor is theirs.

Sample size: 1 (single serial number, owner-supplied) — evidence about this unit, not a verdict on every unit shipped.

Stage-by-stage record

Tracking / RTZPassRTZ fine; 7.8 mils measured between dots
18″ dropsPass
36″ (single)Pass
3×36″Pass
Long-termFailsent for warranty after consistently losing zero — random elevation shifts in two ring sets

Mount setup

Rings/mount: owner-supplied ARC; different rings during long-term use. Ring torque: not stated in source. No torque caveat flagged in the source.

Notes

Drops passed; the failure was recurring ±0.2–0.3 mil random vertical shifts unrelated to impacts. Source also documents a milky outer field-of-view ring.