Optic Passport · Configuration record

Maven RS.5

4-24x50SFPMRAD

This record answers a narrow question: which optic configuration does the indexed evidence describe? Exact retail-SKU identity remains open until primary-source documentation closes it.

Category illustrationExact product image pending verification
Source evaluations11 original source
Documented test stages5/5100% of indexed protocol stages
Identity fields documented61 added by enrichment
Identity fields open6after primary-source review

Identity record

What is documented

Source documented
Brand
Maven
Field-evaluation source
Model
RS.5
Field-evaluation source
Magnification / objective
4-24x50
Field-evaluation source
Focal plane
SFP
Field-evaluation source
Adjustment units
MRAD
Field-evaluation source

These values identify the configuration named in the public evaluation. Enriched claims below retain their own evidence scope so a family manual is never presented as proof of the tested unit's exact UPC or revision.

Evidence enrichment

What the receipts add

Checked 2026-07-24
Reticle identity
Illuminated SHR-MIL
Verified fieldTested unitField evaluation ↗
Current or discontinued lifecycle status
Current manufacturer listing
Evidence leadConfiguration familyMaven ↗

Manufacturer receipts

productRiflescope lineMaven ↗

Scope labels matter: tested unit describes the evaluated optic, exact SKU maps a manufacturer product code, and configuration family applies to the documented model family without proving serial-level identity. A scope match can still remain an evidence lead when its authority or identity chain is incomplete.

Receipts attached

Evaluation history

2022-01
Rokslide field eval

2022-01 zero-retention record

Sample size: 1 · single serial number; process filmed

Tracking / RTZFailadjustment under 2%, but the zero shifted 0.2–0.3 mil three times before the drops
18″ dropsFailfirst 18″ drop produced a 21.5-inch shift; later 18″ drops shifted ≈0.4–0.5 mil
36″ (single)Failmodified 6/12/18/36″ progression — shifted at 12″ and above
3×36″Failshifts on almost every one of 30 drops across both evals
Long-termPasssingle truck-ride zero check held — within an otherwise failed eval

An evaluation documents the tested sample and protocol. It is not automatically a population-level reliability claim.

Make the passport better

Own this optic or its documentation?

A clear model-label photo, packaging label, dated manual, or manufacturer response can close an identity field. Personal reports are useful leads, but they remain separate from verified identity facts.

Send evidence